Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Determination of the Solidification Point (Pour Point) of Pyrolysis Products

The solidification point — internationally reported as the pour point — is a key low-temperature fluidity parameter for pyrolysis oils, tars, and distillate fractions derived from waste plastics, scrap tires, biomass, and coal. Accurate determination in accordance with GB/T 510, GB/T 3535, ASTM D97, ASTM D5949, and ISO 3016 ensures that pyrolysis products can be stored, pumped, transported, and blended safely under cold-climate conditions. This technical article explains the principle, methodology, applicable sample types, and typical applications of solidification point determination for pyrolysis products.

Technical Overview

Pyrolysis products are the liquid oils, tars, and distillate fractions obtained from the thermal decomposition of waste plastics, end-of-life tires, biomass, coal, and sludge. Because these products consist of a broad distribution of paraffins, olefins, naphthenes, and aromatics, their low-temperature flow behavior is a decisive quality parameter for storage, pumping, pipeline transport, and blending. The solidification point defines the temperature at which a cooled specimen ceases to move under standardized conditions; in international practice the closely related pour point — the lowest temperature at which flow is still observed — is the most widely reported equivalent, and its determination is one of the most frequently requested physical tests for pyrolysis-derived fuels.

For pyrolysis products this test is particularly informative. Linear paraffins derived from polyolefin feedstocks crystallize as wax at low temperature and can arrest flow well above 0 °C, whereas aromatic-rich tire oils may remain pourable below −20 °C. Knowing the exact transition temperature allows producers, blenders, and buyers to classify fractions, define tank heating and insulation requirements, and confirm compatibility with diesel-type fuel specifications.

Testing Samples

Waste Plastic Pyrolysis Oil

Oils produced from polyethylene, polypropylene, and polystyrene feedstocks are paraffin- and olefin-rich. Heavy fractions frequently contain microcrystalline waxes that raise the solidification point, so thorough homogenization and representative sub-sampling are essential before analysis.

Tire Pyrolysis Oil

Aromatic-rich oil from scrap tire pyrolysis generally exhibits low pour points, but suspended carbon black and polymer fines must be removed by filtration or centrifugation prior to testing to avoid false flow-arrest readings.

Coal Pyrolysis Tar and Heavy Residues

Coal tar, semi-coking liquids, and pitch-like residues can solidify at or above ambient temperature. Their testing may require preheating and temperature-controlled handling to keep specimens fully liquid until the determination begins.

Biomass Fast Pyrolysis Oil (Bio-oil)

Oxygenated bio-oils typically contain 15–30 % water and display continuous viscosity growth on cooling rather than a sharp wax-crystallization transition. For these products the no-flow point (ASTM D7346) and viscosity–temperature profiling are often more meaningful than the classical pour point.

Distilled and Upgraded Fractions

Naphtha, kerosene-range, and diesel-range cuts obtained by fractional distillation or hydrotreating of crude pyrolysis oil are tested to verify low-temperature fluidity against refinery-grade fuel requirements and customer specifications.

Testing Items

  • Solidification point of petroleum and pyrolysis products (GB/T 510)
  • Pour point — manual tilt method (ASTM D97, ISO 3016, IP 15, GB/T 3535, JIS K 2269)
  • Pour point — automatic pressure-pulsing method (ASTM D5949)
  • Pour point — automatic tilting method (ASTM D5950)
  • Pour point — automatic air-pressure (up-flow) method (ASTM D6749)
  • Maximum and minimum pour point of waxy or crude-like products (ASTM D5853)
  • No-flow point for residual and highly viscous pyrolysis products (ASTM D7346)

Related low-temperature characteristics — cloud point, cold-filter plugging point (CFPP), and low-temperature viscosity — are frequently measured alongside the solidification point to give a complete picture of cold-flow performance.

Testing Methods

Manual Tilt Method (GB/T 510 / ASTM D97 / ISO 3016)

The homogenized, filtered specimen is heated to erase its thermal history, then transferred to a standardized flat-bottomed test jar fitted with a calibrated thermometer. The jar is cooled stepwise through a controlled series of progressively colder baths (ice–water, approximately −18 to −20 °C, and colder cryogenic or mechanical baths down to about −70 °C). In the ASTM D97 procedure the jar is removed at 3 °C intervals, tilted to a horizontal position for five seconds, and examined; the pour point is reported as 3 °C above the temperature at which no specimen movement is observed. In the GB/T 510 solidification-point procedure the jar is inclined 45 degrees for one minute at successively lower temperatures, and the temperature at which the liquid surface shows no movement is recorded as the solidification point. For the same oil, the pour point is conventionally about 2–3 °C higher than the solidification point.

Automatic Methods (ASTM D5949 / D5950 / D6749 / D7346)

Automatic analyzers cool the specimen at a controlled rate, typically 1.5 ± 0.1 °C/min, and apply a defined disturbance at each temperature step: a nitrogen pressure pulse onto the specimen surface (ASTM D5949), a mechanical tilt with optical detection of surface movement (ASTM D5950), or a low-pressure air pulse driving upward flow (ASTM D6749). These methods eliminate operator subjectivity, shorten turnaround time, and permit reporting at 1 °C resolution, which is valuable when tight product specifications must be demonstrated.

Quality Control and Interferences

  • Thermal history: specimens must be preheated and cooled under the prescribed regime, because prior wax crystallization alters the result.
  • Water contamination: ice crystals cause premature flow arrest, particularly in hygroscopic pyrolysis oils; samples should be dried when the method requires.
  • Suspended solids: char, carbon black, and catalyst fines must be removed by filtration or centrifugation unless naturally present and specified.
  • Homogeneity: waxy heavy fractions require gentle preheating (typically to 45 °C or above) and thorough mixing before sub-sampling.
  • Calibration: thermometers, bath temperatures, and tilt or pressure mechanisms must be verified against certified references, and certified reference materials with known transition temperatures should be analyzed routinely.

Manual tilt methods typically achieve repeatability of approximately 3 °C and between-laboratory reproducibility of approximately 6 °C, while automated analyzers generally deliver tighter repeatability on the order of 1–2 °C depending on the selected reporting interval.

Applications

  • Certification of tire- and plastic-derived fuels and blendstocks for delivery to refineries, traders, and fuel distributors
  • Verification of low-temperature pumpability for winter storage, road tanker logistics, rail transport, and marine shipping
  • Blending studies that map the solidification point of pyrolysis oil and diesel mixtures against target fuel grades
  • Process optimization of distillation cut points and hydrotreating severity for diesel-range fraction production
  • Regulatory submissions, customs classification, and research programs supported by accredited third-party laboratories

A reliable solidification-point result supports decisions across the entire value chain, from reactor operating conditions and cut-point selection to blend ratios, tank heating requirements, and cold-climate performance warranties.

FAQ

What is the difference between the solidification point and the pour point?

The solidification point is the temperature at which the specimen no longer moves under the specified tilt condition (GB/T 510), while the pour point is the lowest temperature at which movement is still observed before that point (ASTM D97, ISO 3016, GB/T 3535). For the same oil, the pour point is generally 2–3 °C higher than the solidification point.

Why can plastic-derived pyrolysis oil solidify above 0 °C?

Oils from polyethylene and polypropylene contain significant quantities of linear C20–C40 paraffins. These normal alkanes form interlocking wax crystal networks as the temperature falls, and the network can immobilize the bulk liquid well above the freezing point of water.

How much sample is required and how long does the test take?

A manual determination typically requires about 45–50 mL of homogenized specimen; automatic analyzers often work with smaller volumes. Depending on the expected transition temperature, a single manual determination can take from roughly 40 minutes to two hours because successive colder baths must be used for low-temperature products, whereas automatic instruments complete determinations faster and can queue multiple specimens.

Which method should be chosen for a waxy pyrolysis oil with thermal-history concerns?

ASTM D97 with mandatory preheating is widely accepted for routine control, while ASTM D5853 was specifically developed to determine the maximum and minimum pour points of waxy products by controlling thermal history. Automatic methods such as ASTM D5949, D5950, and D6749 are preferred when high throughput and 1 °C reporting resolution are required.

Can bio-oil be tested by the standard pour-point methods?

Conventional pour-point methods were designed for hydrocarbon products. For oxygenated, water-containing bio-oils the results should be interpreted with caution, and complementary testing — no-flow point (ASTM D7346), viscosity–temperature profiles, and water content — is recommended to adequately describe low-temperature behavior.

How should samples be taken and shipped?

Fill clean, dry, airtight glass or metal containers to at least 90 % capacity to minimize headspace oxidation and water condensation, homogenize waxy samples by gentle warming before sub-sampling, keep them away from extreme heat, and ship them with full chain-of-custody documentation to an accredited third-party laboratory.

Why Choose ZKGX?

  • State-of-the-art analytical equipment
  • Highly qualified scientific team
  • Fast turnaround time