Ubicación: Global + English
Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

PET Degradation Crystallinity Change Testing: Methods, Standards, and Applications

PET degradation crystallinity change testing quantifies how thermal, hydrolytic, photo-oxidative, and biological degradation alter the crystalline/amorphous ratio of polyethylene terephthalate, providing direct evidence of molecular chain scission and residual material performance. Using techniques such as DSC, XRD, FTIR, and density gradient analysis in accordance with ISO and ASTM standards, accredited third-party laboratories track crystallinity evolution before and after aging exposure. This testing is essential for weathering qualification, recycling process control, biodegradation research, and long-term durability prediction of PET products.

Technical Overview

Polyethylene terephthalate (PET) is a semi-crystalline engineering polyester whose mechanical strength, dimensional stability, gas barrier performance, and optical clarity are governed by the ratio of crystalline to amorphous phase, typically ranging from near-zero in amorphous sheet to 30-40% in crystallized or highly oriented products such as stretch-blown bottles and biaxially oriented films.

When PET undergoes degradation, whether by thermal oxidation, hydrolysis, ultraviolet (UV) photolysis, or enzymatic attack, molecular chain scission changes both chain length and chain mobility, and the crystalline/amorphous balance shifts accordingly. A well-documented phenomenon is chemi-crystallization: shortened chains freed from entanglements in the amorphous phase acquire sufficient mobility to crystallize at moderate temperatures, so the measured degree of crystallinity rises even as tensile strength and elongation at break deteriorate. Conversely, severe photo-oxidative surface attack can erode crystal peripheries and reduce crystal perfection, producing broader, lower-temperature melting endotherms.

Crystallinity change testing therefore serves as a sensitive, quantitative marker of degradation depth and mechanism. By comparing the degree of crystallinity, melting behavior, cold crystallization behavior, and related molecular indicators before and after controlled aging, engineers and researchers can establish degradation kinetics, validate stabilization packages, and predict service life. Accredited third-party laboratories routinely perform these measurements under ISO and ASTM frameworks to support product qualification and regulatory submission.

Testing Samples

Virgin and Processed PET Materials

Baseline characterization is performed on the unaged reference material so that every degradation-induced change has a defined starting point. Common baseline sample forms include:

  • PET resin pellets or granules for extrusion and injection molding grades
  • Amorphous PET (APET) sheet and cast film
  • Biaxially oriented PET (BOPET) film for packaging, electronics, and photovoltaic applications
  • Stretch-blown beverage bottles and preforms
  • PET staple fibers, filaments, and nonwoven geotextiles
  • Injection-molded plaques and finished components

Exposed and Aged Specimens

Test coupons are subjected to defined degradation protocols, then retrieved at scheduled intervals for crystallinity comparison. Typical exposure programs include:

  • Xenon-arc accelerated weathering per ISO 4892-2 or ASTM G155 with controlled irradiance, temperature, and humidity cycling
  • Fluorescent UV-condensation weathering per ISO 4892-3 or ASTM G154
  • Natural outdoor weathering and soil burial exposure
  • Hydrothermal aging in water or humid environments at elevated temperatures
  • Long-term thermal-oxidative oven aging for electrical and automotive components
  • Compost incubation per ISO 14855 or ASTM D5338, and enzymatic hydrolysis studies using powdered or film substrates

Specimens are conditioned to equilibrium at 23 °C and 50% relative humidity per ISO 291 or ASTM D618 before measurement. For DSC, representative sections of 5-10 mg are cut from defined locations (for example, the UV-facing surface versus the core) because degradation is frequently depth-dependent.

Recycled and Modified Grades

Recycled PET (rPET) flakes, regranulates, and solid-state polycondensation (SSP) outputs are tested to track crystallinity and molecular weight recovery, as are PET copolymers, filled or nucleated compounds, and experimental biodegradation-targeted formulations.

Testing Items

Crystallinity Parameters

  • Degree of crystallinity before and after degradation, and the change value
  • Melting enthalpy and cold-crystallization enthalpy from which crystallinity is calculated
  • Chemi-crystallization enthalpy developed during isothermal or slow-cooling segments
  • Crystallinity depth profile across thick sections

Thermal Transition Parameters

  • Melting temperature, including double-melting behavior and melting-peak broadening or depression that indicates reduced crystal perfection
  • Cold-crystallization temperature, whose decrease signals improved chain mobility after chain scission
  • Glass transition temperature, which falls as molecular weight drops
  • Crystallization temperature during cooling, reflecting residual crystallizability

Degradation Correlation Parameters

  • Carbonyl index and hydroxyl band growth from FTIR, correlated with crystallinity shift
  • Intrinsic viscosity and viscosity-average molecular weight, used to compute chain scission number
  • Crystallite size and lattice distortion from XRD line-shape analysis
  • Mass loss, surface erosion, and yellowing index as complementary degradation indicators

Testing Methods

Differential Scanning Calorimetry (DSC)

DSC is the primary method, performed per ISO 11357-1 (general principles), ISO 11357-3 (melting and crystallization behavior), ASTM D3418, and the corresponding GB/T 19466 series. A specimen of 5-10 mg is heated from room temperature to approximately 290 °C at 10 °C/min under nitrogen, cooled at a controlled rate, and reheated. The degree of crystallinity is calculated as: Xc = (ΔHm − ΔHcc) / (ΔHm0 × (1 − w)) × 100%, where ΔHm is the melting enthalpy, ΔHcc is the cold-crystallization enthalpy, w is the mass fraction of filler or reinforcement, and ΔHm0 is the reference enthalpy of fusion for 100% crystalline PET, conventionally taken as 140.1 J/g.

The first heating scan is reported for degradation studies because it captures the as-received state, including crystallinity generated by chemi-crystallization during aging. The second heating scan, recorded after erasing thermal history, reveals how molecular weight reduction changes inherent crystallizability.

Wide-Angle X-ray Diffraction (XRD)

XRD provides a structural measurement independent of thermal history. Using Cu Kα radiation over 2θ of 5-40°, the crystalline reflections of the triclinic PET lattice at approximately 16.0°, 17.6°, 21.5°, 23.0°, and 25.6° are separated from the broad amorphous halo near 20.5° by peak deconvolution. Crystallinity is the ratio of crystalline peak area to total scattered area. Crystallite size, estimated through Scherrer analysis, documents whether degradation fragments existing lamellae or promotes new, smaller crystallites. XRD is particularly valuable for heavily degraded or oxidized specimens where DSC baselines may drift.

Fourier Transform Infrared Spectroscopy (FTIR)

ATR-FTIR or transmission FTIR tracks conformer-sensitive bands that reflect crystallinity: the crystalline trans-conformation bands near 973, 848, and 875 cm⁻¹ are ratioed against amorphous gauche bands near 898, 1043, and 1370 cm⁻¹ using an internal thickness reference such as the 1505 or 795 cm⁻¹ band. Simultaneously, the carbonyl index (about 1715 cm⁻¹ normalized) and hydroxyl absorption from 3200-3600 cm⁻¹ quantify oxidation and hydrolysis, allowing direct correlation between chemical degradation and crystallinity change on the same specimen.

Density Gradient Method

Following ASTM D1505, specimens are suspended in a calibrated density gradient column. Using the crystalline density of 1.455 g/cm³ and amorphous density of 1.335 g/cm³, volumetric crystallinity is derived from the measured density. This rapid method is effective for molded articles and pellets but requires void-free samples and a chemically uniform composition.

Supporting Molecular Weight Measurement

Intrinsic viscosity per ASTM D4603, measured in a 60:40 phenol/tetrachloroethane solution at 25 °C, or gel permeation chromatography, supplies the molecular weight data needed to interpret crystallinity shifts. The chain scission number, calculated from the reciprocal change in number-average molecular weight, is plotted against crystallinity increase to confirm chemi-crystallization kinetics.

Applications

  • Outdoor durability qualification of BOPET films, photovoltaic backsheets, graphic films, and glazing laminates subjected to accelerated and natural weathering
  • Bottle-to-bottle recycling programs, where crystallinity control during washing, drying, and solid-state polycondensation determines rPET processability and regulatory compliance for food contact
  • Enzymatic and microbial degradation research, where rising residual crystallinity demonstrates that amorphous regions are hydrolyzed preferentially, guiding engineered enzyme and copolymer development
  • Geotextile and fiber aging studies for soil burial and long-term civil engineering installations
  • Thermal aging life prediction of PET insulating films and automotive components, linking crystallinity drift to retained dielectric and mechanical performance
  • Failure analysis, warranty claims, and litigation support, where crystallinity mapping documents the extent and depth of in-service degradation
  • Academic and industrial R&D for stabilizer screening, nucleating agent evaluation, and degradation mechanism studies

FAQ

Why does PET crystallinity often increase during degradation while mechanical properties decline?

Chain scission shortens molecules and reduces entanglement density, allowing amorphous chain segments to reorganize into crystals, a process called chemi-crystallization. The higher crystallinity typically embrittles the material, so elongation at break and impact strength fall even as the crystalline fraction rises. In advanced photo-oxidation, crystal surfaces may also be attacked, lowering crystal perfection and broadening the melting peak.

Which reference melting enthalpy is used for PET crystallinity calculation?

The widely accepted value is 140.1 J/g for 100% crystalline PET, with literature values spanning approximately 138-140 J/g. Test reports should always state the reference value applied, since using a different value shifts absolute crystallinity by a small but systematic margin.

Why can DSC and XRD give different crystallinity values for the same degraded sample?

DSC measures the thermal manifestation of crystallinity and includes additional crystallization that occurs during the scan itself through the cold-crystallization correction, while XRD measures present structural order and may miss very small or highly imperfect crystallites. Both results are valid; comparisons should always reference the method used, and dual-method reporting is recommended for degraded materials.

Should results be taken from the first or second DSC heating scan?

For degradation assessment, the first heating scan is authoritative because it preserves the crystalline state produced during aging. The second heating scan is useful supplementary data, showing how reduced molecular weight alters the inherent crystallization capability of the material after history is erased.

How much sample is required and what is a typical turnaround time?

DSC requires only 5-10 mg per run, XRD and FTIR are effectively non-destructive on small coupons, and density testing needs several small pellets or slivers. Complete crystallinity change studies on a sample set, including duplicate runs and data reduction, are commonly completed within five to seven working days at accredited third-party laboratories, excluding any aging exposure time.

Can severely degraded or discolored specimens still be tested accurately?

Yes. Heavily oxidized PET may show thermal baseline shifts, minor mass loss, or oxidative exotherms, so hermetically sealed pans, moderate heating rates, and post-test mass verification are applied. Cross-checking DSC against XRD and FTIR ensures that crystallinity values for severely degraded samples remain reliable.

Why Choose ZKGX?

  • State-of-the-art analytical equipment
  • Highly qualified scientific team
  • Fast turnaround time
  • Competitive pricing