REACH SVHC candidate list testing is a critical chemical compliance requirement for manufacturers, importers, and downstream users placing products on the European Union market. Under Regulation (EC) No 1907/2006, articles containing Substances of Very High Concern (SVHC) above 0.1% weight-by-weight trigger mandatory notification and supply chain communication obligations. This article provides a comprehensive technical guide to SVHC candidate list testing, covering regulatory background, sample types, analytical methods, and practical compliance considerations.
Technical Overview
REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is the European Union regulation (EC) No 1907/2006 governing the production and use of chemical substances. Under Article 57 of REACH, a substance may be identified as a Substance of Very High Concern (SVHC) if it meets one or more of the following hazard criteria:
- Carcinogenic, mutagenic, or toxic to reproduction (CMR), category 1A or 1B
- Persistent, bioaccumulative, and toxic (PBT) to the environment
- Very persistent and very bioaccumulative (vPvB)
- Substances of equivalent level of concern, such as endocrine disruptors and respiratory sensitizers
Substances meeting these criteria are added to the Candidate List, which is published and periodically updated by the European Chemicals Agency (ECHA). Since the first list of 15 substances was released in October 2008, the Candidate List has grown to more than 240 entries and continues to expand as new scientific evidence emerges. Typical SVHC substance groups include phthalate plasticizers, bisphenols, per- and polyfluoroalkyl substances (PFAS), polycyclic aromatic hydrocarbons (PAHs), certain heavy metals and their compounds, organotin compounds, and siloxanes such as D4, D5, and D6.
Once a substance appears on the Candidate List, three principal legal obligations arise for producers and importers of articles when the SVHC content exceeds 0.1% (w/w) per article:
- Communication duty under Article 33: suppliers must provide recipients with sufficient information, including the substance name, to allow safe use of the article. Consumers are entitled to the same information free of charge within 45 days of request.
- Notification duty under Article 7(2): ECHA must be notified when SVHC content exceeds 0.1% and total quantity exceeds one tonne per year per producer or importer, unless exposure can be excluded or the substance has already been registered for that use.
- SCIP database notification: under the revised Waste Framework Directive, companies placing articles containing SVHCs above 0.1% on the EU market must submit information to the ECHA SCIP database to support waste treatment and circular economy objectives.
It is important to distinguish the Candidate List from Annex XIV (the Authorisation List) and Annex XVII (the Restrictions List). Candidate List inclusion triggers information duties, whereas Annex XIV inclusion requires authorization for continued use, and Annex XVII imposes specific concentration or use restrictions. Analytical testing against the Candidate List is therefore a fundamental step in demonstrating REACH compliance throughout the supply chain.
Testing Samples
Polymers and Plastics
Plastic materials represent the highest-risk matrix for SVHC contamination, particularly due to phthalate plasticizers (DEHP, DBP, BBP, DINP, DIDP, DIBP), short-chain chlorinated paraffins, and bisphenol A. Samples are typically taken from granules, finished components, films, and sheets.
Metals and Alloys
Metal articles may contain SVHCs such as lead and its compounds, cadmium, chromium (VI) compounds, cobalt salts, and boron-containing substances. Surface coatings and anti-corrosion treatments require particular attention.
Textiles, Leather, and Footwear
Textile and leather products may contain SVHCs including nonylphenol ethoxylates, perfluorinated compounds used in water repellents, aniline, dimethylformamide (DMF), azo dye precursors, and chrome VI from tanning processes.
Coatings, Paints, and Inks
Decorative and functional coatings may incorporate SVHC substances such as lead chromate pigments, phthalates, and certain flame retardants.
Adhesives, Sealants, and Elastomers
Sealant materials, particularly silicone-based products, may contain cyclic siloxanes (D4, D5, D6) and phthalate additives.
Electronics and Electrical Components
Printed circuit boards, cables, connectors, housings, and solder materials require screening for phthalates, flame retardants, lead compounds, and decabromodiphenyl ether.
Packaging Materials
Paper, board, and plastic packaging may contain SVHCs such as bisphenol A in thermal papers and epoxy coatings, phthalates in flexible films, and mineral oil hydrocarbons in recycled board.
Testing Items
Testing programs against the REACH Candidate List can be structured in several ways depending on risk profile, material composition, and supply chain data availability:
- Full Candidate List screening: comprehensive analysis covering all inorganic and organic substances on the current list, typically organized into more than 30 analytical sub-groups.
- Targeted group testing: focused analysis of high-risk substance families such as phthalates, bisphenols, PFAS, PAHs, organotin compounds, flame retardants, and heavy metals.
- Material-based screening: testing driven by the material composition of the article, for example siloxane testing for silicone products or phthalate testing for flexible PVC.
- Updated substance verification: confirmatory testing of newly added Candidate List substances following each ECHA list update.
Key substance groups routinely included in SVHC testing panels are listed below:
- Phthalates and other plasticizers (DEHP, DBP, DIBP, BBP, DINP, DIDP, DNPP, DMEP and others)
- Bisphenols (Bisphenol A, Bisphenol S, Bisphenol B, Bisphenol AF)
- Per- and polyfluoroalkyl substances (PFOA, PFOS, PFHxS, HFPO-DA and related compounds)
- Polycyclic aromatic hydrocarbons (anthracene, benzo[a]pyrene, chrysene and related substances)
- Heavy metals and compounds (lead, cadmium, chromium VI, cobalt, arsenic, boron, and antimony compounds)
- Organotin compounds (DBT, MBT, DOT, TBT and related substances)
- Cyclic siloxanes (D4, D5, D6)
- Alkylphenols and ethoxylates (4-nonylphenol, 4-tert-octylphenol and their ethoxylates)
- Brominated and chlorinated flame retardants (decaBDE, SCCPs, MCCPs, HBCDD)
- Aniline, DMF, and other solvent-related SVHCs
- Endocrine disrupting substances and respiratory sensitizers added in recent updates
Testing Methods
SVHC analysis requires a combination of instrumental techniques because the Candidate List spans inorganic elements, volatile organics, semi-volatile organics, and polymeric compounds. All analytical work should be performed by accredited third-party laboratories operating under ISO/IEC 17025 quality systems. Typical sample preparation involves cutting, cryogenic milling, solvent extraction (with acetone, hexane, or toluene depending on the analyte), and microwave-assisted acid digestion for elemental analysis.
Elemental Analysis
Heavy metals such as lead, cadmium, cobalt, arsenic, and boron are quantified using inductively coupled plasma optical emission spectrometry (ICP-OES) or inductively coupled plasma mass spectrometry (ICP-MS) following acid digestion. X-ray fluorescence (XRF) spectrometry is widely used as a rapid, non-destructive screening technique to prioritize samples for confirmatory wet chemical analysis.
Organic Analysis by GC-MS
Gas chromatography coupled with mass spectrometry (GC-MS) is applied to phthalates, PAHs, organotin compounds (after derivatization), short-chain chlorinated paraffins, and other semi-volatile organic substances following solvent extraction.
Organic Analysis by HPLC and LC-MS/MS
High-performance liquid chromatography (HPLC) with fluorescence, UV, or mass spectrometric detection is used for thermally labile or non-volatile substances including bisphenols, alkylphenol ethoxylates, perfluorinated compounds, and certain flame retardants.
Chromium VI Determination
Hexavalent chromium in coatings and passivation layers is determined by UV-Visible spectrophotometry using the diphenylcarbazide colorimetric method after alkaline extraction, in accordance with recognized procedures such as ISO 17075 for leather.
Quality Control and Reporting
Results are reported in mg/kg (ppm) with method detection limits typically well below the 1000 mg/kg (0.1%) regulatory threshold. Reports should include substance identification, CAS numbers, measured concentrations, measurement uncertainty, and clear pass or fail conclusions relative to the 0.1% w/w limit.
Applications
SVHC Candidate List testing supports regulatory compliance and market access across a broad range of industries:
- Electrical and electronic products: consumer electronics, appliances, cables, and IT equipment requiring coordinated REACH and RoHS compliance strategies.
- Toys and childcare articles: products with intensive skin and mouth contact requiring rigorous chemical safety demonstration.
- Textiles, apparel, and footwear: garments, leather goods, and footwear subject to brand restricted substances list (RSL) requirements aligned with REACH.
- Automotive components: interior parts, wiring harnesses, coatings, and elastomers supplied into the EU automotive supply chain, often managed through IMDS material declarations supported by test data.
- Packaging and consumer goods: food contact materials, cosmetics packaging, and household products requiring SVHC assessment under REACH and packaging regulations.
- Medical devices and industrial equipment: products requiring documented chemical risk assessment as part of overall regulatory conformity.
Test reports also serve essential business functions, including supplier due diligence, customer declarations, response to enforcement authority requests, SCIP database submissions, and defense against product recall or market withdrawal actions.
FAQ
What does the 0.1% threshold mean in practice?
The 0.1% weight-by-weight threshold applies per article, not per homogeneous material or per product. For simple articles this is straightforward, but for complex objects containing multiple components, the article definition must be assessed on a case-by-case basis. In practice, testing is performed on homogeneous materials, and compliance conclusions are drawn for each component article within the final product.
How often is the Candidate List updated?
The ECHA Candidate List is updated periodically, historically approximately twice per year, with each update adding new substances. Companies should monitor ECHA announcements and reassess product compliance after each update, including targeted testing of newly listed substances.
Is SVHC testing legally mandatory?
REACH does not explicitly mandate laboratory testing, but producers and importers must know the SVHC content of their articles to fulfill notification, communication, and SCIP obligations. Testing by accredited third-party laboratories is the most reliable means of generating this knowledge when supplier declarations or material data are unavailable or incomplete.
What is the difference between the Candidate List, Annex XIV, and Annex XVII?
The Candidate List triggers information and notification duties at 0.1% w/w. Annex XIV is the Authorisation List; substances on it cannot be used after a sunset date unless authorized. Annex XVII imposes specific restrictions on manufacture, placement on the market, and use. A substance may progress from the Candidate List to Annex XIV over time, so ongoing monitoring of all three lists is recommended.
How long does SVHC testing take?
Typical turnaround time for full Candidate List screening is five to ten working days after sample receipt, depending on sample complexity and laboratory workload. Targeted single-group testing can often be completed within three to five working days.
Can I rely on supplier declarations instead of testing?
Supplier declarations and material data systems are valuable first-line tools, but the legal responsibility for article compliance rests with the producer or importer. Risk-based verification testing through accredited third-party laboratories remains best practice, particularly for new suppliers, recycled materials, and high-risk product categories.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time
- Competitive pricing